No.15, Fuping Road, Panyu District, Guangzhou, China +86-13922173260 [email protected]
Cold storage pallet racking engineered for chiller and freezer environments. Hot-dip galvanized against condensation, adjustable beam levels and capacities up to 2,000 kg per pair.
A cold room is the most expensive space in your facility — every cubic meter is refrigerated, insulated and paid for year after year. Yet most cold storage operators lose that investment twice: once to racking that corrodes from condensation, and once to wasted vertical space that forces a bigger, costlier cold room than the inventory actually needs..
Two things decide whether that investment pays back: how much of the room you actually fill, and how long the steel inside it lasts.
This series specification applies to both. It is implemented after manufacturing, effectively protecting welds and cut edges—where corrosion typically begins—from condensation, frost cycles, and wash water erosion. The beam height is adjustable in 50 mm increments, allowing frozen pallets of varying heights to fit snugly against the structure and preventing cold air from remaining above each layer of goods. Anchoring and anti-collision protection are standard features, not afterthoughts, as the primary challenge this rack faces is forklifts operating through foggy, icy aisles.

Why Cold Storage Racking Is Different
Cold storage attacks ordinary racking in ways ambient warehouses never do. Condensation drips and freezes, floors stay wet from washdown, forklift operators work in poor visibility and icy conditions, and every empty slot wastes paid refrigeration. Cold-storage-grade racking answers each one:
Cold room challenge |
How this racking answers it |
Wasted refrigerated space |
75 mm adjustable beam pitch packs pallets tight |
Forklift impacts in haze/frost |
Standard floor anchoring + optional aisle protection |
Long equipment service life |
Maintenance-free galvanized surfaces |
Food-adjacent hygiene |
Smooth, cleanable surfaces; open design for airflow |

Key Features
Hot-dip galvanized construction—coating applied after fabrication, protecting weld points and cut edges where corrosion starts first.
Cold-room engineered range—designed for chiller through deep-freeze duty, confirmed per project.
Adjustable beam levels—50 mm pitch re-slots in minutes to fit changing pallet and carton heights.
Floor anchoring standard—anchor pattern engineered for the racking, the load and the cold-room floor.
Impact protection options—aisle-end posts, corner guards and row spacers sized for cold-room forklift traffic.
Hygienic, cleanable design—open frame minimizes dust traps and simplifies washdown between storage cycles.
Modular expansion—add bays and levels without welding or re-engineering the existing installation.
Specifications:
Table shows standard ranges—dimensions, capacities and finishes are customizable to your project.
Parameter |
Standard Range |
Material |
Q235 cold-rolled steel |
Upright frame profile |
90×60×2.0 / 100×70×2.0 mm Q235 cold-rolled steel |
Beam profile |
Double-C, 50×100 – 80×120 mm |
Beam load capacity (per pair) |
500 – 3,000 kg |
Upright height |
1.5 – 10 m |
Bay width |
1.8 – 3.6 m |
Beam levels |
2 – 6 (adjustable, 75 mm pitch) |
Surface treatment |
Powder coat optional |
Floor fixing |
Expansion anchors (included) |
Optional protection |
Aisle-end posts, corner guards, row spacers, back nets |
Certifications |
CE, ISO 9001, SGS |
Load labelling |
Rated load label on every beam level |

Application Scenarios
1. Chiller Rooms
Dairy, produce and fresh-food storage where condensation is constant. Galvanized frames survive the humidity; adjustable beams adapt to mixed crate and pallet heights.
2. Freezer Warehouses
Frozen food, seafood and ice cream demand dense, accessible storage. High-capacity galvanized bays keep deep-freeze inventory organized and rotation-ready.
3. Cold-Chain Distribution Hubs
Transit cold rooms between transport legs need fast in/out access. Selective beam racking keeps every pallet directly reachable for rapid cross-docking.
4. Blast Chill & Rapid Cool Zones
Rapid temperature-change areas stress coatings hardest. Galvanized-after-fabrication finishes handle thermal cycling without the flaking that painted racking suffers.
5. Pharmaceutical & Temperature-Controlled Storage
Regulated storage requires traceability and cleanable surfaces. Load labels, open frames and galvanized finishes support audit-ready, hygienic cold storage.

Safety & Compliance
Cold rooms punish shortcuts that ambient warehouses forgive — here is how the system is specified against that.
Ratings hold at temperature. Load figures on the labels apply in chiller and deep-freeze rooms alike, so nobody has to derate by guesswork when stock moves between zones.
Anchoring and impact protection are specified together. Frosted visors and glare turn aisle collisions into the dominant damage mode in freezers; protecting the upright is cheaper than replacing a loaded bay.
No repainting cycle in a food zone. The galvanized coating is maintenance-free, which removes a recurring shutdown that painted racking forces on operators.
Documentation for auditors. Load calculation, structural drawings, plus CE, ISO 9001 and SGS files on request — the paperwork cold-chain and pharmaceutical audits usually ask for.
Seismic anchoring available where local codes require it.